| Standards No. | Standard Title & Description | Summary of Key Requirement Changes | Effective Date |
| UL 1082 | Household Electric Coffee Makers And Brewing-type Appliances, 5th Edition | Clarification for the Hydrostatic Pressure Test for Espresso Makers, which requires that both steam outlets (one through the cofee filter and one through a "frothing nozzle" be blocked and pressure tested, either in combination or individually, whichever results in the maximum on both systems). | July 15, 2006 |
| UL 2353 | Single And Multi-Layer Insulated Winding Wire, 1st Edition | Previously conducted heat shock data will need to be reviewed to verify that wire Recognized in sizes less than 0.2 mm and those greater than 1.0 were tested on three samples made with the correct diameter mandrel as specified in the new, expanded Table 10.1. | July 20, 2006 |
| Previously conducted heat shock data will need to be reviewed to verify that wire Recognized for medical & dental applications were dielectrically tested per the voltages indicated in clause 12.4. |
| UL 234 | Low Voltage Lighting Fixtures For Use In Recreational Vehicles, 5th Edition | Wet location water shield shall have a minimum mechanical impact Relative Temperature Index (RTI), or be subjected to Thermal Conditioning Test. | July 21, 2006 |
| UL 542 | Fluorescent Lamp Starters, 9th Edition | Braided or non-braided wiring are allowed for manual starter leads, but with different lead insulation temperature rating requirements, i.e. not less than 75°C if the leads are provided with an outer braid, and not less than 90°C when not provided with an outer braid. | September 1, 2006 |